Powered by Google translate

Please note we have enabled Google translate for your country.

This is a machine translation, and may not be perfect in all cases.

You can turn this off at any time, and return to the original English by selecting “English” at the top of the drop down menu.

Unlock Your Market Potential with the AT5600 :
Test, Transform, Triumph !

Elevate your sales game with the AT5600, a cutting-edge testing solution designed to cater to the diverse needs of your customers' markets.
Experience unparalleled versatility as you explore the unlimited possibilities for testing different transformer types.
With the AT5600 by your side, success is just a test away!

Achieve Quality and Profitability Across Every Market

With its ability to test any magnetic component type, the AT5600 empowers you to efficiently deliver excellence across diverse market sectors.

In the ever-evolving electronics landscape, where miniaturization reigns supreme and customer demands vary, magnetic component manufacturers can rely on the AT5600 to establish the pinnacle of quality assurance.

For OEMs and CEMs, the AT5600 is a game-changer. Experience lightning-fast, 100% incoming test, drastically reducing the need for time-consuming rework caused by faulty components.
Efficiency and productivity soar as you streamline your production processes.

Additionally, the AT5600's comprehensive range of tests allows you to effortlessly assess multiple product types on a single production line.
Seamlessly reconfigure test programs, eliminating complexities and paving the way for seamless adaptability.

Power supplies

Power supplies are perhaps the most familiar areas of application for transformers, but even here the requirements are diverse.
Ferrite-based transformers are ubiquitous in SMPS PSUs, lighting ballasts, inverters and UPS's. Chokes and inductors are also required in these end products, both to control output noise and ripple, and on the AC side for EMC filtering. An area where the AT5600 testing excels.

Medical

Transformer manufacturers are increasingly differentiating their products by reliability and safety compliance.
High-reliability aerospace and medical electronics all represent areas of substantial growth, where the ability to perform 100% testing is key.
The AT5600's built-in Hi-Pot, Surge and Stress Watts capability allows you to meet this need.

Communications

In communications applications, devices such as xDSL filters and Ethernet LAN transformers have distinctive test requirements.
Accurate measurements of return loss, insertion loss and longitudinal balance, as well as hi-pot testing, are all possible using the integrated AT5600 platform.

Audio

Transformers are also frequently used in audio products, to provide isolation and impedance matching.
Here the AT5600’s capability to test under normal operating conditions, and at high frequencies, is a key benefit along with its specific tests designed for audio transformers

 

Expand Your Testing Horizons with Over 40 Comprehensive Test Types

Experience the power of 100% testing at real operating voltages, a crucial advantage for components intended for safety-critical applications.
By maintaining tight control over the manufacturing process, we drastically reduce field failures, ensuring the utmost reliability and peace of mind
.

Through our patented technologies, including advanced impedance measurement and core energization techniques, we revolutionize the time-to-test and enhance measurement accuracy.
Speed and precision merge seamlessly, elevating your testing efficiency to unprecedented levels.

Furthermore, our tests are meticulously engineered to cater to specific technologies, offering you a wide spectrum of test methods.
Embrace a comprehensive coverage that leaves no stone unturned, ensuring thorough evaluations tailored to your unique requirements.

Winding Resistance

Used to check for integrity of assembly, correct wire gauge, and shorted turns on all windings

Series Or Parallel Inductance

To assess core material, core assembly, gapping and inductance operation over 20 Hz - 3 MHz

Turns Ratio

Used to check components are correctly wound with the correct number of turns. Also confirms correct phasing.

Leakage Inductance

To check for close coupling of the magnetic flux between windings, or confirm a specific LL value if desired.

Magnetising Current

Understand and manage core losses with direct testing of larger transformers at high speed 1-270 V AC

AC and DC Hi-Pot

Check and confirm isolation and product safety with integrated high voltage testing as part of your standard test sequence

Surge Testing

A stress test to identify shorted turns or weakened insultation. To validate quality and longevity of build

DC Bias testing

Testing for core saturation characteristics, when in the presence of DC bias signals

 

Streamline Your Testing with the AT5600: One Station, Endless Possibilities

Experience the convenience of a single test station that caters to all your magnetic component needs.
The AT5600 is your ultimate solution, capable of effortlessly conducting all the production and characterization tests necessary for any transformer or magnetic component type.

Say goodbye to the hassle of multiple testing setups and embrace the simplicity of consolidated testing with the AT5600. 

Explore our range of testing examples by clicking on the component type below.
Witness firsthand the versatility and power of the AT5600, empowering you to achieve excellence in testing, no matter your specific requirements.

CONTACT US

Need Advice? Have Questions or Comments?

If you have any questions, or would like to try an AT5600 Demo Unit yourself then please contact us

Please log in to see purchasing or trial options